<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15196</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: Picker vacuum sensed plate before vacuum turned on, remove plate
from picker \ncheck Picker Vacuum Threshold
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Platesetter_3244</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Check the value of pvt.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Check that there is no plate on the picker.
</text></DescriptionText>
</OperatorAction>
<Cause>
During ale init, it is assumed that there is no plate on the picker. (picker vacuum
is not turned off). The picker vacuum is then turned ON and the vacuum checked against
pvac_threshold, if it is above the threshold then, either there was a plate on there all
along (and it must be manually removed), or the system is sensing a plate when there
isn't one. This could be caused by an incorrect pvt value or a blockage in the sucction
cups.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/sat_cal_pvt.xml</LinkAddress><LinkTitle>NVS: sat pvt</LinkTitle></Link>
<Link><LinkAddress>../commands/pvac.xml</LinkAddress><LinkTitle>Command: pvac</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:56 2008 PST
</Updated>
<Links>
</Links>
</Error>